EasyManua.ls Logo

ABB OmniCore V400XT - Page 282

ABB OmniCore V400XT
466 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NoteArticle numberSpare part
3HAC081951-001Break resistor bleeder assembly
Required tools and equipment
NoteArticle numberEquipment
Content is defined in section
Standard toolkit for controller on
page 424.
-Standard toolkit
-ESD protective wrist band
Required documents
NoteArticle numberDocument
3HAC082020-008Circuit diagram - OmniCore
V400XT
Removing the break resistor bleeder
Preparations
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 29.
1
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 45.
2
xx2300001842
Removing the rear cover on page 184.Remove the rear cover of the controller.3
Opening the door on page 182.Open the door.4
Removing the break resistor bleeder
Note/IllustrationAction
Remove the cable ties.1
Continues on next page
282 Product manual - OmniCore V400XT
3HAC081697-001 Revision: A
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.2.18 Replacing the break resistor bleeder
Continued

Table of Contents