Note/IllustrationAction
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 45.
2
xx2300001842
Screws: Torx, countersunk screw M4x10 (4
pcs)
Insert the motor connector into the front
panel from inner side of the cabinet and
fasten it with the screws.
3
Tightening torque: 2.7 Nm±10%.
xx2100000813
Reconnect any connectors disconnected
at removal.
4
Secure the motor connector cables with
the velcro on the frame of the cabinet.
Tip
Use the same position as from removing
the motor connector.
5
Concluding procedure
Note/IllustrationAction
Closing the door on page 183.Close the door.1
Continues on next page
292 Product manual - OmniCore V400XT
3HAC081697-001 Revision: A
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.3.2.1 Replacing the motor connector
Continued