NoteArticle numberEquipment
-ESD protective wrist band
Required documents
NoteArticle numberDocument
3HAC082020-008Circuit diagram - OmniCore
V400XT
Removing the power cable and power cable cover
Note/IllustrationAction
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 45.
1
Disconnect the FlexPendant from the
controller.
2
xx1800001189
Remove the attachment screws for the
power cable cover.
3
xx1800001190
Remove the power cable cover.4