EasyManua.ls Logo

ABB OmniCore V400XT - Page 97

ABB OmniCore V400XT
466 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A protective stop device needs to be connected to the protective stop input. See
example below.
14
1
3
15
10
12
11
9
16
0V_IO_EXT
24V_CH1_EXT
GS_CH1_P
GS_CH1_N
0V_IO_EXT
24V_CH2_EXT
Customer provided
protec!ve stop device
GS_CH2_P
GS_CH2_N
A2.K5.X14
xx2300000995
The protective stop input can be powered from an external power supply:
Customer_24V_CH1
Customer_24V_CH2
Customer_0V_CH1
Customer_0V_CH2
Customer provided power
0V_IO_EXT
24V_CH1_EXT
0V_IO_EXT
24V_CH2_EXT
A2.K5.X14
GS_CH1_P
GS_CH1_N
GS_CH2_P
GS_CH2_N
14
13
15
10
12
11
9
16
Customer provided
protec!ve stop device
xx2300000996
Continues on next page