- 133 - UMC22-FBP FieldBusPlug / Issue: 02.2008
V 6
Universal Motor Controller UMC22-FBP
Software version 4.0
7.8.3 Interface and data overview
Hardware Inputs / Outputs
1)
depending on the parameterization
2)
displayed on the Control Panel
3)
Time can be elongated.
4)
Run-time: max. running time open  close. Use Parameter Star-delta starting time. Busdata details see 4.2.2.
Terminal 13 14 15 16 17 18
Device input
(to bus)
DI0
(Check-back
OLS)
DI1
(Check-back
CLS)
DI2
1)
(Multifunction
input)
DI3
(Check-back
OTS / CTS)
DI4
1)
(local:
open)
DI5
1)
(local:
close)
Terminal 7 8 9
Device output
(from bus)
DO0
(contactor
OPEN)
DO1
(contactor
CLOSE)
DO2
1)
(Fault
output)
Monitoring telegram, digital
Bit No. 7 6 5 4 3 2 1 0
Byte 0 WARNING FAULT
LOCAL
CONTROL
-
REVERSE
LOCK-OUT
TIME
RUN
FORWARD /
Opening
OFF
(aus)
RUN
REVERSE/
Closing
Byte 1
DI5
1)
(UMCinput)
DI4
1)
(UMCinput)
DI3
(UMCinput)
DI2
1)
(UMCinput)
DI1
(UMCinput)
DI0
(UMCinput)
--
Monitoring telegram, analog
Byte 0 and Byte 1: Motorcurrent in % of set current
Command telegram, digital
Bit No. 7 6 5 4 3 2 1 0
Byte 0 -
FAULT
RESET
AUTO
MODE
PREPARE
EMERGENCY
START
SELF
TEST
RUN
FORWARD /
Open
OFF
RUN
REVERSE /
Close
Byte 1
DO2
1)
(UMC output)
--- ---
Diagnosis telegram
Bit No. 7 6 5 4 3 2 1 0
Fault
Byte 0
Sametime
OLS and CLS
F009
2)
Self test failed
F010
2)
Fault signal
on DI0, DI1
or DI2
1)
F011
2)
OLS 1 0
without
close
command
F012
2)
CLS 1 0
without
open
command
F013
2)
OLS 1 0
not within
3 s
3)
after
close
command
F014
2)
CLS 1 0
not within
3 s
3)
after
open
command
F015
2)
OTS 1 0
but not OLS
(intermediate
position)
F016
2)
Fault
Byte 1
Overload (trip)
fault
trip
2)
Motor blocked
F002
2)
Communi-
cation fault
F003
2)
Parameter out
of range
F004
2)
Current
check-back
fault
1)
F005
2)
OLS 0 1
without
open
command
F006
2)
CLS 0 1
without
close
command
F007
2)
CTS 1 0
but not CLS
(intermediate
position)
F008
2)
Warning
Byte 2
Motor current
high threshold
1)
Motor current
low threshold
1)
-
Cooling time
running
°C
2)
-
Self test
running
buSy
2)
Emergency
start
prepared
Run-time
exeeded
4)
Warning
Byte 3
If Parameter out of range: Pamameter number (leading two stages of the parameter, e.g. "02" Current factor)
If Self test fauled: Self test error number (only for service)
In all other cases:
Phase loss
trip
2
Fault on DI2
F024
2)
Faut on DI1
F023
2)
Fault on DI0
F022
2)
Earth fault
F020
2)
PTC
short-circuit
F019
2)
PTC
wire break
F018
2)
PTC
temperature
F017
2)