Operation Manual / 4 Product description / A100-L
9 Taking a turbocharger out of operation / 9.3 Procedure with one in-
stalled turbocharger
© Copyright 2017 ABB. All rights reserved. HZTL4034_EN Revision K June 2017
Product h [mm] d1 [mm] d2 [mm]
A165-L 3.5 … 4.0 13 20
A170-L 3.5 … 4.0 13 20
A175-L 4.0 … 5.0 17 28
A180-L 4.0 … 5.0 21 34
A185-L 4.5 … 6.0 21 34
A190-L 4.5 … 6.0 25 39
Table45: Required washers (01)
Part number A165-L A170-L A175-L A180-L A185-L A190-L
57005 M12
50Nm
M12
50Nm
M16
80Nm
M20
160Nm
M20
160Nm
M24
280Nm
Table46: Tightening torque (57005)
1. Remove screws(57005).
2. Fit and tighten screws (57005) with high-temperature grease and washers (01) in accord-
ance with the table.
9.3.4 Continuing to operate the engine
Continue to operate engine in accordance with enginebuilder's instructions. Do not exceed
prescribed power reduction and maximum turbocharger speed.
Page 93 / 106