TCS-Compact 6 Putting into operation
EN - 13
Connect the device via the compressed-air hose.
The operating pressure should be 6 bar.
If the compressed air supply is under 6 bar, the cutting capacity of the wire cutter and the speed of the
compressed air motor will be reduced.
This will reduce the performance of the torch cleaning station.
1 Compressed air connection DN 10
Fig. 7 Compressed air connection
1
NOTE
We recommend to operate the device with cleaned and oiled compressed air.
An applicable maintenance unit is available as accessory.