11. Timer 0/1/2 A96G174/A96S174 User’s manual
90
Figure 42. Input Capture Mode Operation for timer1
Figure 43. Express Timer Overflow in Capture Mode
T1CNTH/L
Value
Interrupt
Request
(FLAG1)
TIME
1
2
3
4
5
6
n-2
n-1
n
Interrupt Interval Period
0
Count Pulse Period
P
CP
Up-count
T1BDRH/L Load
EINT1 PIN
T1CNTH/L
Interrupt
Request
(FLAG1)
XX
H
Interrupt Interval Period = FFFF
H
+01
H
+FFFF
H
+01
H
+YY
H
+01
H
EINT11 PIN
Interrupt
Request
(T1IFR)
FFFF
H
FFFF
H
YY
H
00
H
00
H
00
H
00
H
00
H