SECTION V
PROGRAM SELECTIONS (PL #01-PL #07)
PL #01 – CONTROL SETTINGS
SELECT LANGUAGE
This location determines in what language ALL messages will be displayed. The possible selections are English
and Japanese.
SELECT TEMP SCALE
Temperature-related programs are programmable to be operated in either Fahrenheit (°F) or Celsius (°C). The
temperature scale selection is made in “PL #01 TEMP SCALE”. Programs affected are:
1. Temperature Display Mode
2. Drying Temperatures
3. Cool Down Temperatures
IMPORTANT: When changing the temperature conversion status from Fahrenheit to Celsius, or vice
versa, ALL the temperatures will be changed accordingly. The Phase 7 dual
microprocessor controller (DMC) computer automatically calculates and converts
the temperatures in these programs to the previously set value. For example,
when changing from °F to °C, if the drying temperature was set for 150°F, the
Phase 7 DMC (computer) will change to 66°C (+/- 1°Celsius).
SELECT BUZZER MODE
This location determines whether the buzzer will sound at the end of each Wrinkle Guard Cycle. This option is
toggled ON/OFF. Refer to the Wrinkle Guard description in Section III for an explanation of Wrinkle Guard
functionality.
BEEP COUNT 1 TO 9 BEEPS
If the Buzzer Mode is set to “ON”, this location determines how many times the buzzer will beep at the end of
a Wrinkle Guard Cycle.
SELECT DRY MODE
This option determines whether the dryer operates in Free Mode or Coin Mode.