Introduction
1
Bio-inert Materials
Bio-inert Materials
For the Bio-inert LC system, Agilent Technologies uses highest quality
materials in the flow path (also referred to as wetted parts), which are widely
accepted by life science scientists, as they are known for optimum inertness to
biological samples and ensure best compatibility with common samples and
solvents over a wide pH range. Explicitly, the complete flow path is free of
stainless steel and free of other alloys containing metals such as iron, nickel,
cobalt, chromium, molybdenum or copper, which can interfere with biological
samples. The flow downstream of the sample introduction contains no metals
whatsoever.
Table 1 Used Bio-inert materials
Module Materials
Agilent 1260 Infinity II Bio-inert Pump
(G5654A)
Titanium, gold, platinum-iridium, ceramic,
ruby, PTFE, PEEK
Agilent 1260 Infinity II Bio-inert Multisampler
(G5668A)
Upstream of sample introduction:
Titanium, gold, PTFE, PEEK, ceramic
Downstream of sample introduction:
PEEK, ceramic
Agilent 1260 Infinity II Bio-inert Manual Injector
(G5628A)
PEEK, ceramic
Agilent 1260 Infinity II Bio-inert Analytical Fraction Collector
(G5664B)
PEEK, ceramic, PTFE
Bio-inert Flow Cells:
Standard flow cell bio-inert, 10 mm, 13 µL, 120 bar ( 12 MPa) for MWD/DAD,
includes Capillary Kit Flow Cells BIO (p/n G5615-68755) (G5615-60022)
(for Agilent 1260 Infinity II Diode Array Detectors DAD G7115A)
PEEK, ceramic, sapphire, PTFE
Bio-inert flow cell, 8 µL, 20 bar (pH 1–12) includes Capillary Kit Flow Cells BIO
(p/n G5615-68755) (G5615-60005)
(for Agilent 1260 Infinity II Fluorescence Detector FLD G7121A/B)
PEEK, fused silica, PTFE

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 1260Infinity II Bio-inert FractionCollector and is the answer not in the manual?

Agilent Technologies 1260Infinity II Bio-inert FractionCollector Specifications

General IconGeneral
BrandAgilent Technologies
Model1260Infinity II Bio-inert FractionCollector
CategoryLaboratory Equipment
LanguageEnglish