Motion State Instructions 
 
  Rockwell Automation Publication MOTION-RM002H-EN-P-February 2018  31 
Pre-Charge  1  The drive is waiting for the DC Bus to fully charge, 
that is, the DC Bus Up status bit is cleared. Once the 
DC Bus reaches an operational voltage level, that is, 
DC Bus Up status bit is set, the   axis transitions to the 
Stopped state. 
The drive's power structure is always disabled in this 
state, that is, the Power Structure Enabled status bit 
is cleared. Any attempt to enable the drive via the 
Axis Control mechanism while in this state is 
reported back to the controller as an error in the 
Response Status and the axis remains in the 
Pre-charge state. 
Stopped  2  In the Stopped state, the drive's inverter power 
structure should either be disabled and free of 
torque, that is, the Power Structure Enabled status 
bit is cleared, or held in a static condition via an 
active control loop, that is, Power Structure Enabled 
status bit is set. The drive cannot initiate motion in 
the Stopped state nor can the drive respond to a 
planner generated command reference, that is, the 
Tracking Command status bit is cleared. 
In general, the axis should be at rest. However, if you 
apply an external force or torque to the load, a brake 
may be needed to maintain the rest condition. In the 
Stopped state, main power is applied to the drive 
and the DC Bus are at an operational voltage level. If 
there are any Start Inhibited conditions detected 
while in this state, the axis transitions to the Start 
Inhibited state. If an Enable request or one of the Run 
Test service requests is applied to an axis in the 
Stopped state, the motion axis transitions to the 
Starting state. 
Starting  3  When an Enable request is given to an axis in the 
Stopped or Stopping state while it is performing a 
Flying Start, the axis immediately transitions to the 
Starting state. In this state, the drive checks the 
following conditions before transitioning to the 
Running state. 
•  Brake Release delay time 
•  Induction Motor flux level 
The drive control and power structures are activated 
during the Starting state, that is, the Power Structure 
Enabled status bit is set. But the command reference 
is set to a local static value and does not track the 
command reference derived from the motion 
planner, that is, the Tracking Command status bit is 
cleared. If all the starting conditions are met, the axis 
state transitions to either the Running state or the 
Testing state. 
Running  4  The drive's power structure is active, that is, the 
Power Structure Enabled status bit is set. 
Additionally, the selected Control Mode is enabled 
and actively tracking command data from the 
controller-based or drive-based motion planner 
output to affect axis motion, that is, the Tracking 
Command status bit is set.