Interpret the Attribute Tables
Chapter 3
Rockwell Automation Publication MOTION-RM003I-EN-P - February 2018 145
ID Access Rule Attribute Name B E F P V T Conditional Implementation
628 Set Power Loss Threshold N - Y Y Y Y
630 Set Power Loss Time N - N N N N
590 Set Proving Configuration - - Y Y Y Y V26/V27
376 Set* Ramp Acceleration - - Y - Y - Derived
377 Set* Ramp Deceleration - - Y - Y - Derived
378 Set Ramp Jerk Control - - Y - Y -
375 Set* Ramp Velocity - Negative - - Y - Y - Derived
374 Set* Ramp Velocity - Positive - - Y - Y - Derived
613/354 Set Resistive Brake Contact Delay - - N N N N PM Motor only
1333 Set Rotary Motor Damping Coefficient - - Y Y Y Y Rotary Motor only
2312 Set Rotary Motor Fan Cooling Derating - - N N N N Rotary Motor only
2311 Set Rotary Motor Fan Cooling Speed - - N N N N Rotary Motor only
1330 Set Rotary Motor Inertia - - Y Y Y Y Rotary Motor only
1332 Set Rotary Motor Max Speed - - Y Y Y Y Rotary Motor only
766 Set Safe Stopping Action - - Y Y Y Y O-Enum V31
1 = Current Decel (F/Y)
2 = Ramped Decel (FV/Y)
767 Set Safe Stopping Action Source - - Y Y Y Y O-Enum V31
1 = Running Controller (Y)
765 Set Safe Torque Off Action - - Y Y Y Y O-Enum V26/V27
1 = Current Decel Disable (F/Y)
2 = Ramped Decel Disable (FV/Y)
128 = DC Injection Brake (FPVT/N)
129 = AC Injection Brake (FPVT/N)
759 Set Safe Torque Off Action Source - - Y Y Y Y O-Enum V31
1 = Running Controller (Y)
629 Set Shutdown Action N - N N N N O-Enum
1 = Drop DC Bus (FPVT/N)
370 Set Skip Speed 1 - - Y - - -
371 Set Skip Speed 2 - - Y - - -
372 Set Skip Speed 3 - - N - - -
373 Set Skip Speed Band - - Y - - -
833 Set SLAT Configuration - - - - Y -
834 Set SLAT Set Point - - - - Y -
835 Set SLAT Time Delay - - - - Y -
610 Set Stopping Action - - R R R R O-Enum
1 = Current Decel Disable (F/Y) V26/V27
2 = Ramped Decel Disable (FV/Y)
3 = Current Decel Hold (PV/Y)
4 = Ramped Decel Hold (V/Y)
128 = DC Injection Brake (FPVT/N)
129 = AC Injection Brake (FPVT/N)
612 Set Stopping Time Limit - - Y7 Y Y Y (F/V26/V27)

Table of Contents

Other manuals for Allen-Bradley ControlLogix

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley ControlLogix and is the answer not in the manual?

Allen-Bradley ControlLogix Specifications

General IconGeneral
CommunicationEtherNet/IP, ControlNet, DeviceNet, DH+
I/O CapacityUp to 128, 000 I/O points (varies by configuration)
RedundancySupported (with specific modules)
Programming SoftwareRockwell Automation Studio 5000 Logix Designer
Operating Temperature0°C to 60°C (32°F to 140°F)
Programming LanguagesLadder Logic, Function Block Diagram, Structured Text, Sequential Function Chart
ModularityYes
CertificationsUL, CE
Processor TypeMultiple options available, including standard, safety, and extreme environment processors
Power SupplyMultiple options available, including standard and redundant power supplies with various voltage ranges (e.g., 24V DC, 120/240V AC)

Related product manuals