100 Using the High-Speed Counter and Programmable Limit Switch
Low Preset Reached (LPR)
The LPR (Low Preset Reached) status flag is set (1) by the HSC sub-system
whenever the accumulated value (HSC:0.ACC) is less than or equal to the
low preset variable (HSC:0.LOP).
This bit is updated continuously by the HSC sub-system whenever the
controller is in an executing mode.
Description Address Data Format
HSC Modes
(1)
(1) For Mode descriptions, see HSC Mode (MOD) on page 107.
Type User Program Access
LPR - Low
Preset
Reached
HSC:0/LPR bit 2 to 7 status read only