EasyManuals Logo

Allen-Bradley PowerFlex 755 User Manual

Allen-Bradley PowerFlex 755
354 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #270 background imageLoading...
Page #270 background image
270 Rockwell Automation Publication MOTION-UM003K-EN-P - January 2019
Chapter 12 Homing
APR Fault Generation
A project download, restore from a memory card, or a ControlFLASH
firmware update after one of these events can cause an APR fault:
Axis configuration
Change in any of the axis attributes that impacts the absolute
machine position.
Attribute changes
Offline edits of the axis attributes or configuration do not cause an
APR fault until after download occurs.
Online edits of certain attributes result in an immediate APR fault.
Changing the axis feedback device or feedback polarity without
downloading the project also generates an immediate APR fault.
Axis hardware change or malfunction.
Axis hardware resource insufficiency.
Hardware resource insufficiencies are detected only during download
or ControlFLASH firmware update.
Reconnection of the drive axis.
When an APR fault occurs, the actual position of the axis is set to the feedback
reference position of the axis. This value is read from the absolute encoder of
the axis. The APR Fault clears the axis homed status bit.
Downloading of a Project
The following checks are made during a download of a project:
1. Does the Axis exist? If not, then it is a new axis and no APR fault occurs
or is generated.
2. Does the Scaling Signature match the saved Scaling Signature?
3. Does the Feedback Serial Number match the saved Feedback Serial
Number?
If these three checks pass, absolute position is restored.
During operation, the system monitors changes to that following attributes.
These attributes do not affect the Scaling Signature or result in the loss of the
absolute machine reference and therefore do not generate an APR Fault.
•Conversion Constant
Position Unwind
•Travel Mode

Table of Contents

Other manuals for Allen-Bradley PowerFlex 755

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley PowerFlex 755 and is the answer not in the manual?

Allen-Bradley PowerFlex 755 Specifications

General IconGeneral
CategoryAC Drive
Amperage2.2…1470 A
Output Voltage0 to Input Voltage
Output Current2.2…1470 A
EnclosureIP20, IP30, IP54
CommunicationsEtherNet/IP, ControlNet, DeviceNet
I/ODigital, Analog, Encoder, Relay
SafetySafe Speed Monitor
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overload, Short Circuit, Ground Fault, Overtemperature
Operating Temperature-10°C to 50°C (14°F to 122°F)
Storage Temperature-40°C to 70°C (-40°F to 158°F)
Humidity5…95% noncondensing
AltitudeUp to 1000m (3300ft) without derating
Voltage200-240V AC, 380-480V AC, 500-600V AC, 690V AC
Input Voltage200-240V AC, 380-480V AC, 500-600V AC, 690V AC
Control MethodSensorless Vector