43
* Configuring a Break Time Zone that extends over the Shift Time Zone and the Overtime Zone will result in a
programming error.
Example of This Kind of Conflict:
Shift End Time 17:00 Overtime Beginning Time 17:30
Break Beginning Time 16:45 Break End Time 17:45
* Configuring a Break Time Zone that includes a Midnight Shift Time Zone will result in a programming error.
Likewise, configuring a Break Time Zone that includes the Overtime Beginning Time will result in a
programming error.
Example of This Kind of Conflict:
Shift End Time 17:00 Overtime Beginning Time 18:00
Break Beginning Time 17:30 Break End Time 18:30
■ Basic Programming Rules for Hourly Worker Parameters
* Configuring the same Beginning Time for the B, C and/or D Time will result in a programming error.
Example of This Kind of Conflict:
B Time Zone Beginning Time 13:00
C Time Zone Beginning Time 13:00 D Time Zone Beginning Time 21:00