EasyManua.ls Logo

Ammann APH 50/75 - Main Ten an Ce Schedule

Ammann APH 50/75
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6.2 Main ten an ce schedule
45020000-2 HbmG gnu thci dreV nna mmA 9102/90
6. Main ten an ce
71
In ter vals
dai ly 20 h 50 h 100 h 250 h 500 h 1000 h
if ne ces-
sary
Works
Cle an ma chi ne
l
Check en gi ne oil le vel
1)
l
Chan ge en gi ne oil
1)
l
3)
l
Chan ge en gi ne oil fil ter
1)
l
3)
l
Check air fil ter
1)
l
Chan ge air fil ter ele ment
1)
l l
Check suc ti on air in ta ke
1)
l
Drain wa ter (Fuel tank)
1)
l
Chan ge fuel fil ter
1)
l
Check val ve clea ran ce
1)
l
3)
l
Ex ci ter: Check oil le vel
l
Ex ci ter: Chan ge oil
2)
l
3)
l
Check hyd rau lic oil le vel
l
Chan ge hyd rau lic oil
2)
l
3)
l
Chan ge re turn fil ter ele ment
2)
l
3)
l
Chan ge ven ti la ti on fil ter
2)
l
3)
l
Cle an suc ti on fil ter
2)
l
3)
l
Check the hyd rau lic hose li nes
l
Check rub ber buf fers
l
Check scre wed con nec tions for
tight ness
l
3)
l
1)
See en gi ne ope ra ting ma nu al.
2)
Mi ni mum once a year.
3)
For the first time.

Table of Contents