Appendix C – Virtual NetLinx Master
126
Instruction Manual – DXLink™ Twisted Pair Transmitters/Receiver
2. Click the New button.
The New Telnet Address dialog box opens.
3. Enter the default static IP address for the module: 192.168.1.2 and click OK.
4. Select the new address in the List of Addresses.
5. Click the Select button and click OK.
6. A Telnet session opens.
7. At the prompt (>), type SET DEVICE <num> and press Enter.
For the variable <num>, the valid range of device numbers is 0 to 31999.
Setting a device number does not require a reboot to take effect.
8. At the prompt, type SET CONNECTION and press Enter.
9. Specify TCP for the connection and the PC’s static IP address for the Master.
The Transmitter or Receiver displays under the Virtual Master and is now ready for file transfers.
Note: The process can be repeated for additional Transmitters and Receivers.
File transfers via a Virtual Master:
IRL file transfers, see page 73
Firmware file transfers, see page 105
Important: Once you have finished using the Virtual Master – If you disabled a network connection
before setting the PC’s static IP address, be sure to disable the Virtual Master’s network connection
and enable the original connection.

Table of Contents

Other manuals for AMX DXLink

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AMX DXLink and is the answer not in the manual?

AMX DXLink Specifications

General IconGeneral
CategoryReceiver
DimensionsVaries by model
WeightVaries by model
HDCP ComplianceYes
Video Input SignalHDMI
ControlRS-232, IR, Ethernet
Input ConnectorHDMI
Output ConnectorHDMI
Operating Temperature0° to 50° C
Humidity10% to 90% non-condensing
Storage Temperature-20° to 70° C

Related product manuals