Upgrading Modero Firmware
106
VG Series Modero Touch Panels
8. Select the panel’s KIT file from the Files section.
9. Enter the Device value associated with the panel and the System number associated with the Master (listed in the
OnLine Tree tab of the Workspace window). The Port field is greyed-out.
10. Click the Reboot Device checkbox. This causes the touch panel to reboot after the firmware update process is
complete. The reboot of the panel can take up 30 seconds after the firmware process has finished.
11. Click Send to begin the transfer. The file transfer progress is indicated on the bottom-right of the dialog (B in
FIG. 92).
12. As the panel is rebooting, temporarily unplug the USB connector on the panel until the panel has completely
restarted.
13. Reconnect the USB connector to the panel.
14. Right-click the associated System number and select Refresh System. This causes a refresh of all project systems,
establishes a new connection to the Master, and populates the System list with devices on your particular system.
15. Confirm the panel has been properly updated to the correct firmware version.
FIG. 92 Using USB for a Virtual Master transfer