Firmware Pages and Descriptions
117
VG Series Modero Touch Panels
Panel Information Page
The Panel Information page (FIG. 102) centers around Modero panel properties such as the resolution used, on-board
memory, firmware, address/channel information, and string information.
The elements of the Panel Information page are described in the table below:
Setup Page Elements (Cont.)
Display/Panel Timeout: Sets the length of time the panel can remain idle before activating the sleep mode. When the
device goes into sleep mode, the LCD is powered-down.
• Press the UP/DN buttons to increase/decrease the time until the panel
times out. Range = 0 - 240 minutes.
• Use this button to set the timeout value to zero and disable the sleep mode.
• Note: Display timeout values affect battery performance. Small timeout values increase
the life of the battery charge. Greater timeout values may require more frequent battery
charging.
Inactivity Page Flip
Timeout:
Sets the number of minutes of inactivity before the panel automatically flips to a pre-selected
touch panel page. When the device goes into this inactivity mode, the LCD does not power-
down.
• Press the UP/DN buttons to increase/decrease the time the panel can remain inactive
before it flips to the preset page. Range = 0 - 240 minutes.
• Use this button to set the timeout value to zero and disable the inactivity page flip mode.
• The touch panel page used for the Inactivity page flip is shown within a small Inactivity
Page field.
Panel Brightness: Sets the display brightness level of the panel.
• Press the UP/DN buttons to adjust the brightness level. Range = 0 - 100.
• The on-screen bargraph can be dragged to adjust the Brightness level which is then
reflected as a corresponding numeric value within the Panel Brightness field.
FIG. 102
Panel Information page (takes its’ information from the touch panel)
Panel Information Page Elements
Back: Returns you to the previously active touch panel page.
Connection Status icon: This visual display of the connection status allows the user to have a current visual update of
the panel’s connection status regardless of what page is currently active.
• A Lock only appears on the icon if the panel has established a connection with a currently
secured target Master (requiring a username and password).
Panel Type: Displays the model of the Modero panel being used.
Firmware Version: Displays the G4 firmware version being used by the panel.
• Verify you have the latest version from www.amx.com.
Setup Port: Displays the setup port information/value being used by the panel.
High Port: Displays the high port (port count) value for the panel.
High Address: Displays the high address (address count) value for the panel.
High Channel: Displays the high channel (channel count) value for the panel.
This information is retrieved from
the Modero panel