Panel Calibration
78
VG Series Modero Touch Panels
3. After the "Calibration Successful." message appears, press anywhere on the screen to continue and return to the
Setup page.
Testing your Calibration
1.
Press and hold down the on-screen Calibration button for 6 seconds to enter the Calibrate page.
2. Press anywhere on this page to confirm the on-screen crosshairs match your touch points.
3. If the crosshairs do not appear directly below your LCD touch points, press the Back button and recalibrate the
panel using the above steps.
4. Exit the Calibrate page by pressing the Back button to return to the Protected Setup page.
FIG. 67 Touch Panel Calibration Screens
The request to touch the crosshairs
is the first on-screen message
Calibration successful is the second
on-screen message that appears
On-screen crosshairs used for
calibration of the touch device
after the calibration process is
completed
If the calibration was improperly set and you cannot return to the Calibrate
page (through the panel’s firmware); you can access this firmware page via
G4 WebControl where you can navigate to the Protected Setup page and press the
Calibrate button through your VNC window.
This action causes the panel to go to the Calibrate page seen above, where you can
physically recalibrate the actual touch panel again using the above procedures.