Firmware Pages and Descriptions
133
VG Series Modero Touch Panels
Protected Setup Page
The Protected Setup page (FIG. 115) centers around the properties used by the panel to properly communicate with the
NetLinx Master. Enter the factory default password (1988) into the password keypad to access this page.
The elements of the Protected Setup page are described in the table below:
FIG. 115 Protected Setup page-showing default values
Protected Setup Page Elements
Back: Saves the changes and returns you to the previously active touch panel page.
Connection Status icon: This visual display of the connection status allows the user to have a current visual update
of the panel’s connection status regardless of what page is currently active.
A Lock only appears on the icon if the panel has established a connection with a
currently secured target Master (requiring a username and password).
Device Number: Opens a keypad that is used to set and display the current device number.
Device Name: Opens a keypad that is used to set and display the current device name.
Synchronize Device Names: Press this button to synchronize the device name of the panel with the device name
registered with the Master.
Reboot Panel: Pressing this button causes the panel to restart after saving any changes.
Keyboard Layout: Displays the listing of supported international keyboard settings. The following list allows
the end-user to specify which international keyboard is being connected to the Modero
touch panel and then which characters should be reflected within the G4 Computer Control
and TakeNote applications:
- None (default), Spanish, Italian, French, German, Swiss, UK, and US
Note: You must be using a standard 101 button keyboard to accurately utilize this feature.
Modero uses the open-source VNC character standards to transmit the character
information to a target device such as a PC.
One of the issues which occurred in the past was that some 101-key foreign keyboard
character sets were being incorrectly represented via the Computer Control and Take
Note applications.
For example: Spanish keyboards consisting of Castilian character sets such as tilde
(
é) were being miscommunicated by the VNC application to the source computer and
as a result, passwords were not properly being entered.
The VNC - Computer Control keyboard drivers found in earlier Modero firmware
(build 57 or earlier) were using an English type/character set which was not fully
utilizing all available foreign characters.
Several different countries have produced 101-key international keyboards, each with
their own unique set of keys occupying the keyboard. Several of these keys are
specific to the language they are used with.
Provides access to the panel firmware
pages by enabling the grey front
- Setup page (after a 3 second press/hold)
- Calibration page (after a 6 second
setup access button:
press/hold)