Upgrading Modero Firmware
110
VG Series Modero Touch Panels
9. Click the Reboot Device checkbox. This causes the touch panel to reboot after the firmware update process is
complete. The reboot of the panel can take up 30 seconds after the firmware process has finished.
10. Click Send to begin the transfer. The file transfer progress is indicated on the bottom-right of the dialog (FIG. 95).
11. Click Close (after the panel reboots) to return to the main program.
12. Right-click the associated System number and select Refresh System. This causes a refresh of all project systems,
establishes a new connection to the Master, and populates the System list with devices on your particular system.
Upgrading Accessory Devices via an IP Address
The following accessory devices are firmware upgradeable:
NXA-BASE/B Battery Base (FG2255-10)
NXA-RGB card (FG2260)
NXA-AVB/RGB Breakout Box (FG2254-11)
These devices are not given a unique device numbers which would ordinarily appear within the Online Tree tab of
NetLinx Studio. They appear below the target which they are either communicating with (NXA-AVB/RGB) or a part of
(NXA-BASE/B or NXA-RGB card) as seen below in FIG. 96.
The only way to upgrade the firmware of an accessory item is to send the accessory’s firmware through a target panel. Its
this panel’s device number which is entered within the Send to NetLinx Device transfer dialog in Studio.
Step 1: Prepare the NXA-BASE/B for firmware transfer
Before beginning with this section:
Unplug any connectors from the rear of the NXT panel (power, Ethernet, etc.).
Refer to the Installing the NXA-BASE/B to an NXT Modero Panel section on page 38 for installation
procedures to mount the NXT atop the battery base.
Verify your NXA-BASE/B is securely attached to the bottom of the NXT panel.
FIG. 96 Location of Firmware version information within NetLinx Studio
NXA-RGB
NXA-AVB/RGB
(BOB version)
firmware
Target Panel Device #
NetLinx Studio Online Tree tab Accessory’s corresponding firmware page
Firmware can also be downloaded to accessory items via a direct USB connection
using the PC as a Virtual Master (Upgrading the Modero Firmware via the USB
port section on page 103). In this case, you will still need to know the System and
Device Number information of the target panel. For a more detailed description of
how to setup this type of connection, refer to the Configuring and Using USB with a
Virtual Master section on page 81.
DO NOT PLACE BATTERIES IN THE BASE BEFORE CONNECTING IT TO THE
NXT PANEL. Insert batteries into the NXA-BASE/B ONLY AFTER the base has been
installed onto the bottom of the NXT panel.
Having batteries in the base before connection can damage the battery base.