Firmware Pages and Descriptions
130
VG Series Modero Touch Panels
Refer to the Displaying Stream Content section on page 153 for the procedures used to configure the TPD4 touch panel
pages and media stream source (using MAX-CSE for example purposes).
Battery Base Page
This page (FIG. 113) allows you to alter/set the power warning preferences, monitor battery status information, and alter
the display times for the battery warnings. The fields on this page are populated with information after the panel is
connected to an optional NXA-BASE/B Battery Base containing up to two NXT-BP batteries.
This page is ONLY available on Modero Table Top panels (NXT) using an NXA-BASE/B. The elements of the Battery
Base page are described in the table below:
Streaming Settings Page Elements (Cont.)
Contrast: Use the UP/DN buttons to alter the contrast level of the incoming signal.
Range = 0 - 255, default = 128.
Saturation: Use the UP/DN buttons to alter the color saturation level of the incoming signal.
Range = 0 - 255, default = 128.
Hue: Use the UP/DN buttons to alter the hue level of the incoming signal.
Range = 0 - 255, default = 128.
FIG. 113
Battery Base page
Battery Base Page Elements
Back: Saves the changes and returns you to the previously active touch panel page.
Connection Status icon: This visual display of the connection status allows the user to have a current visual update of
the panel’s connection status regardless of what page is currently active.
A Lock only appears on the icon if the panel has established a connection with a
currently secured target Master (requiring a username and password).
Charge Status: Time Remaining (
blue
) indicates the amount of charge time (use) remaining on the
batteries within the connected NXA-BASE/B.
Time Until Charged (green) indicates the amount of time remaining until the batteries
installed within the connected NXA-BASE/B are fully charged.
Range = 0:00 - 12:59. This is read in HH:MM, hours and minutes.
Panel Shutdown: The Panel Shutdown UP/DN buttons alter the timeout value (in minutes).
This value determines the number of minutes that would need to pass before the panel
automatically shuts-down.
Once shutdown, the unit would have to be restarted. A zero value disables this feature.
Range = 0 - 240, default = 0 min.
Low Battery Warning: The Low Battery Warning UP/DN buttons alter the time value (in minutes) available on the
battery (for use) before the panel displays a low battery warning.
Range - 10 - 45, default = 15 min.