Firmware Pages and Descriptions
131
VG Series Modero Touch Panels
Battery Base Page Elements (Cont.)
Very Low Battery Warning: The Very Low Battery Warning UP/DN buttons alter the time value (in minutes) available
on the battery (for use) before the panel displays a very low battery warning. This indicates a
near-term panel shutdown.
Range = 3 - 15, default = 5 min.
- This value can never exceed the Low Battery Warning value.
When the NXT-BP batteries (installed within the NXA-BASE/B battery base) reach
a point where they need to be recalibrated.
- A recalibration pop-up screen appears to ask whether or not you choose to recalibrate
the batteries at this time.
Battery Status fields: This section provides the ability to monitor the current battery charge levels and charge
qualities:
The Combined Charge Status bargraph indicates the combined power charge
available from both internal battery connection slots (bargraph range = 0 - 100).
The Battery One Charge Status bargraph indicates the power charge available on the
Slot 1 internal battery connection (bargraph range = 0 - 100).
The Battery One Quality bargraph indicates the physical capacity (quality) of the
battery. Quality is the percentage of actual capacity vs. its rated capacity.
For optimal performance, a battery should be replaced when the quality rating
drops below 80%.
The Battery Two Charge Status bargraph indicates the power charge available on the
Slot 2 internal battery connection (range = 0 - 100).
The Battery Two Quality bargraph indicates the physical capacity (quality) of the
battery. Quality is the percentage of actual capacity vs. its rated capacity.
The Base Version field indicates the firmware version being used by the NXA-BASE/B
Battery Base connected to the NXT Modero panel.
The Battery Level Port field indicates the port being used to report the combined
charge status level back to the NetLinx Master on (set in TPD4).
The Battery Level field indicates the level being used to report the combined charge
status level back to the NetLinx Master on (set in TPD4).
Battery Power Brightness
Limit:
The DISABLE/DISABLED button acts as a power save feature with two available choices:
Disable - activates the brightness limit set on the Modero panel and is used
to conserve battery power. Activating this feature causes the panel to function at 80%
of full brightness and overrides the Panel Brightness value set on the Setup page. This
extends the battery usage time.
Disabled - (illuminated when selected) deactivates this power save feature and makes
the panel use the specified Panel Brightness level set on the Setup page.
The term "quality" (in the context of a battery), refers to the current capacity relative to
the batteries’ rated capacity. For example, after constant use, a battery may be
operating at 75% of its rated capacity even though it might be fully charged. In this
case, the battery could be incorrectly reporting its’ information back to the battery
base and then consequently relating this information back to the Battery Base page.
A battery can be recalibrated using an optional NXT-CHG (battery charger).