Firmware Pages and Descriptions
141
VG Series Modero Touch Panels
Refer to the Using G4 Web Control to Interact with a G4 Panel section on page 98 for more detailed instructions on how
to use the G4 Web Control Settings page with the new web-based NetLinx Security application.
G4 Web Control Page Elements
Back: Saves the changes and returns you to the previously active touch panel page.
Connection Status icon: This visual display of the connection status allows the user to have a current visual update
of the panel’s connection status regardless of what page is currently active.
A Lock only appears on the icon if the panel has established a connection with a
currently secured target Master (requiring a username and password).
G4 Web Control Settings: Sets the IP communication values for the touch panel and contains:
Enable/Enabled The Enable/Enabled button allows you to toggle between the two G4 activation
settings:
- Enable - deactivates the G4 Web Control feature on the panel.
- Enabled - activates the G4 Web Control feature on the panel and allows an external
PC running a VNC client to access the panel (after the remaining fields are
configured).
Network Interface Select Displays the detected method of communication to the web:
Wired is used when a direct Ethernet connection is being used for communication to
the web. This is a default setting if no wireless interface card is detected by the panel.
Wireless is used when a wireless card is detected within the internal card slot. This
method provides an indirect communication to the web via a pre-configured Wireless
Access Point.
Web Control Name Allows you to enter a unique alpha-numeric string that is used as the display name of the
panel within the Manage WebControl Connections window of the new NetLinx Security
browser window.
This Web Control tab displays a G4 icon alongside the link to the Web Control Name
given to this panel (FIG. 121).
Web Control Password Allows you to enter the G4 Authentication session password associated for VNC web
access of this panel.
Web Control Port Allows you to enter the port value that the VNC Web Server runs on.
Default value is 5900.
Maximum Number of
Connections
This read-only field displays the maximum number of users that can be simultaneously
connected to the target panel via the web.
Default value is 1.
Current Connection Count This read-only field displays the current number of users connected to the target panel via
the web. This value cannot exceed the Maximum number field.
G4 Web Control Timeout: Sets the length of time (in minutes) the panel can remain idle (no cursor movements)
before the session is closed and the user is disconnected.
Minimum value = 0 minutes (panel never times-out)
Maximum value = 240 minutes (panel times-out after 240 minutes/4hours)
FIG. 121
Sample relationship between G4 Web Control and Mange WebControl Connections window