Installation Procedures: 17" Panels
66
VG Series Modero Touch Panels
2. Verify the incoming RJ-45, Ethernet, and any other audio/video cables have been properly threaded through the
wiring knockouts on the left of the conduit box. Leave enough slack in the wiring to accommodate any re-
positioning of the panel.
3. Connect all data and power wiring connectors to their corresponding locations along the side of the (un-powered)
NXD touch panel.
Verify the terminal end of the power cable is not connected to a power supply before plugging in the 2-pin
power connector.
The USB connectors can be from either a USB extension cable, or a wireless USB RF transmitter.
4. Test the incoming wiring by connecting the panel connections to their terminal locations and applying power. Verify
the panel is receiving power and functioning properly to prevent repetition of the installation.
5. Disconnect the terminal end of the power cable from the connected power supply.
6. Carefully slide the main NXD unit (B in FIG. 56) into the conduit box, so the Mounting Tab lies flush against the
conduit box (C in FIG. 56).
7. Insert and secure four securing #8 flat-head Mounting Screws into their corresponding holes located along the sides
of the NXD (FIG. 56). These #8 screws are not included within the CB Installation Kit and must be provided by the
installer.
8. Place the magnetic faceplate (A in FIG. 56) back onto the main NXD unit (B in FIG. 56). Make sure to align the
Microphone, Light, and PIR Motion sensor locations to their respective openings on the front bezel/faceplate.
9. Reconnect the terminal RJ-45, Ethernet, and any optional audio/video wiring to their respective locations (outside
the conduit box) on either the NXA-AVB/RGB, Ethernet port, or NetLinx Master.
10. Reconnect the terminal power connector on the 12 VDC-compliant power supply and apply power.
FIG. 56 Wall Mount panel installation configuration of a CB-TP17 in a pre-wall construction
B - Main NXD unit consists of
C - Optional CB-TP17
Mounting Screws
(not included)
secure the NXD to
Stud
the touch panel and backbox housing
conduit/wallbox
Support block
Mounting Tab
Do not use these
tabs to mount
the conduit /wallbox
These are ONLY used to
secure the main unit to the CB
A - Faceplate
(bezel)
the Conduit Box
Four #8 flat-head
Don’t disconnect the connectors from the touch panel. The unit must be installed with
the attached connectors before being inserted into the conduit box.