Medium-consistency pump MC
STANDARD, C-01-000000
Rev. 0, 2010.02.09 OPERATION Kap.6 , Seite 7 of 12
GRZ-2698572-v1-Operation.FM
6.8 Shutdown
Automatic
shutdown
When using the group stop, all necessary steps are carried out
automatically by the DCS.
Manual shutdown Carry out the following steps for manual shutdown:
Shut the chemical inlet branch
Close degassing line
Stop stock feed to stand pipe.
Close the valve in the delivery pipe
Shut down pump
Shut down sealing water valve
WARNING
If there is a danger of the pump liquid freezing, the pump and pipes
should be emptied!
DANGER
Before longer downtime (>24h) the standpipe has to be thoroughly
flushed with water to prevent the creation of biogas.
Shut the chemical inlet branch before flushing.
Shutdown according to Ch. 6.8