Medium-consistency pump MC
STANDARD, C-01-000000
Rev. 0, 2010.02.09 ERECTION WORK and TRANSPORT Kap.4 , Seite 7 of 12
GRZ-2698569-v1-Erection.FM
4.5.1 Mounting the medium-consistency pump
Foundation The foundation should be made according to ANDRITZ AG's foundation
plan.
The following preparations have to be made prior to placing the
medium-consistency pump on the foundation:
Mark axes and elevations on the foundation.
Check the workmanship of the foundation before beginning erection
work.
Mounting and
foundation work
The foundations are to be laid according to the following table.
Step Activity
1 Place pump unit on a level foundation with supporting rails (h
= 50 - 100 mm). (
Fig. 4-3 or Abb. 4-9)
Raise the pump according to Chapter 4.3
Align with the suction branch or other reference points.
2 Drill through holes in base frame and insert dowel pins.
(
Abb. 4-9)
3 Insert threaded rod from above. Screw on 2 washers and 2
hexagon nuts between the foundation and the base frame and
screw the threaded rod into the dowel pin. Tighten the
threaded rod with fastening nut in the dowel pin at the required
tightening torque.
4 Raise the pump unit with the setting nut and remove the
support rails.
Raise the pump according to Chapter 4.3
5 Set the pump unit with the setting nut and tighten with the
required tightening torque using the fastening nut for the base
frame. For more detailed information about required torques
please see the maintenance chapter.
6 Cut off the threaded rod with 5 mm allowance and debur.
7 Grout base frame with shrink-free grouting compound.
Hardening period 1 - 2 days. At least concrete strength
category according to EN206-1. C20/25
8 Mount the motor if it has not yet been installed. Draw the
drilling coupling half flush onto the motor stub and secure on
the feather key with a set screw.
The base frame is designed to accommodate the largest
possible motor for the type of pump used.
If a smaller motor is mounted, the motor bases (blue polymer
concrete) also supplied must be used.
Through bolts or threaded rods cut to a suitable length are
used to secure the motor in place. These must be tightened
with the required tightening torque.
Tab. 4-1 Foundations