EasyManua.ls Logo

Andritz MC - Maintenance Schedule

Andritz MC
106 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Medium-consistency pump MC
STANDARD, C-01-000000
Rev. 0, 2010.02.09 MAINTENANCE Kap.7 , Seite 4 of 22
GRZ-2698573-v1-Maintenance.FM
7.4 Maintenance schedule
In addition to the work outlined below, personnel must also carry out
maintenance and work required for normal operations
/MEDIUM CONSISTENCY PUMP MC/ OPERATION/ NORMAL
OPERATION).
Monthly The following maintenance work is to be carried out at monthly intervals.
6-monthly The following maintenance work is to be carried out at 6-monthly
intervals.
Annually The following maintenance work is to be carried out at annual intervals.
Component Activity
Bearings
• Check temperature
• Vibration measurements
• Check oil level
• Check for strange noises
Shaft with bearing
• Check for smooth running
Coupling
• Check alignment
• Check pads for wear
Mechanical seal
• Check for leaks
• Check for wear
Pipework
• Check for leaks
Complete pump
• Check for leaks
• Clean
Tab. 7-2 Monthly maintenance work
Component Activity
Complete pump
• Check mounting of pump on the
foundation
Motor
• Check mounting of motor on the
foundation
Tab. 7-3 6-monthly maintenance work
Component Activity
Complete pump
• Complete service according to instructions
from Andritz AG
(Oil change, impeller and
fluidisator check, etc.)
Tab. 7-4 Annual maintenance work