Step 18.
Press the DELTA soft key to display the difference
between M2 and M1 in dB and frequency. (The delta
function only displays the difference of M2, M3, or
M4 with respect to M1.)
Step 19.
Press the BACK and the MAIN soft key to return to
the Main Menu.
Adjusting a Limit
Step 20.
Press the LIMIT key (Figure 2-1, page 2-0) to call up
the Scale Menu.
Step 21.
If the Limit needs to be turned OFF, press the LIMIT
soft key on the Scale Menu. If the Limit needs to be
turned ON, press the LIMIT soft key again. This will
open the Limit parameter for entry. If needed, enter
the desired numerical value using the keypad or the
Up/Down Arrow key (Figure 2-1, page 2-0). Press
ENTER when the data entry is complete.
Step 22. If you wish to have an audible beep when the trace is
above the limit line, press the OPT soft key from the
Main Menu (page 2-8).
Step 23.
Press the B2 soft key from the Option Menu (page
2-13) to toggle the limit beep indicator ON.
Saving a Setup
Step 24.
Press the SAVE SETUP key (Figure 2-1, page 2-0).
Step 25. Enter the desired numerical value (1 to 6) using the
Up/Down Arrow key. Press ENTER when data entry
is complete.
Recalling a Setup
Step 26.
Press the RECALL SETUP key.
2-39