EasyManuals Logo

ATEQ F670 User Manual

ATEQ F670
214 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #144 background imageLoading...
Page #144 background image
Sheet #678u – Starting up
Version 1.04a User guide ATEQ 6th series Page 3/4
When the window on the right is displayed, the
instrument is ready to test
Note: the device goes on the last program
carried on.
Pr 001
LEAK TEST
3. SCREEN DÉTAIL
100.0
mbar
OK
0.300
cm3/m
0.000
Pr1
cm3/mn
0.0 s
Green light:
Pass part.
Red light:
Fail Part
Flashing Red light:
Alarm
Green and red lights:
Reworkable Part
Run
pro
g
ram
Measurement
unit
Test result
value
Remaining time
of the current
phase
Vertical lines
test result
Test Result
Pressure
instruction
value
Test Reject
value

Table of Contents