Loading...
Sheet #611u – Mini Valve
Version 1.04a User guide ATEQ 6th series Page 1/1
MINI VALVE
This function is dedicated to small part applications (volume below 10 cm
3
) and has a base time
of 0.01s instead of 0.1 s.
The programming of an ATEQ with a mini valve is identical to the programming of the standard
ATEQ.
Parameter to be set is: A-Z Diff (differential Auto Zero). This time can be reduced as long as the
obtained values are stable and repeatable.
1. PROCEDURE
Activate the function or check if i
t checked.
Press the
key, the cursor slide to the
right hand.
2#4#/2T
(70%6+10
ŹMINI-VALVE : No
More functions…
By using the arrows, select
"Yes" and validate with the
key.
2#4#/2T(70%6+10
Ź MINI-VALVE : Yes Ż
More functions…
Adjust the differential Auto-Zero value if
needed, the default value is proven stable
(500 ms).
T
(70%6
/+0+Ä8#.8
Ź Diff A-Z : 0.50 s