(1) Cooling air flow
(2) Compressor side
(3) Outside
4.7 Installation instructions for dryer by-pass
Description
It is not required to connect a bypass, a blind flange is foreseen ex factory. If by-passing of the dryer is required,
connect the compressor to the air net as shown below. The compressed air outlet temperature sensor (G3/8”)
and the pressure transducer (1/4” -18 NPT) must be relocated to the delivery pipe upstream of the shut-off
valve. The new location is indicated by “x”. The temperature sensor and pressure transducer must be positioned
perpendicular to the air flow at all time (as shown).
Instruction book
106 2920 1728 05