3.14 Modifying compressor/motor settings
Control panel
Function
To modify a number of settings. Consult the menu flow in section Control programs.
Procedure
Starting from the Main screen (see Main screen menu):
Press the key “Menu” (F1).
Press the arrow down key (1) until “Modify parameters” is followed by an arrow pointing to the right.
Activate the menu by pressing tabulator key (2).
The first option (“Compressor Motor”) will be followed by a right pointing arrow. Press key (2): the first
item “Setpoint 1” and its setting will appear.
Use keys (1) to scroll until the parameter to be modified is followed by a horizontal arrow.
For each parameter, the modifying procedure is similar to the example below.
Modifying the net pressure setpoints
If desired, the operator can program two setpoints “Setpoint 1” and “Setpoint 2”.
Consult the section above for selecting the option “Setpoint 1”.
The screen shows that the current setting is 7.0 bar(e).
To modify this setting, press the key “Modify” (F2); The setting will blink.
The key “Limits” can be used to find out the limitations for the parameter. Use the scroll keys (1) to change
the value.
Press the key ”Program” (F1) to program the new value or the key “Cancel” (F3) to cancel the modification
operation (the original value will be retained).
If required, the procedure to modify “Setpoint 2” is similar to the description above.