10 Problem solving
10.1 Problem solving
Warning
Before carrying out any maintenance, repair work or adjustment, stop the compressor,
press the emergency stop button and switch off the voltage. Close the air outlet valve and
open the manual condensate drain valves.
Open and lock the isolating switch.
The operator must apply all relevant Safety precautions.
Control panel
Faults and remedies
A service message appears on the display
Stop the compressor and carry out the indicated service actions.
Reset the message:
Press the “Menu” key (3).
Press key (1) until “Service” is followed by an arrow pointing to the right. Activate the menu by pressing
key (2).
Press the “Reset” key (3); the timer is reset to 0.
A shut-down warning message appears on the display
The alarm LED will light up indicating that the temperature at the outlet of the compressor elements is too
high. The message disappears as soon as the cause of the problem is remedied.
Instruction book
2920 1728 05 145