EasyManua.ls Logo

Atlas Copco GA 160 VSD

Atlas Copco GA 160 VSD
166 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A condensate trap is installed downstream of the air cooler to prevent condensate from entering the air outlet
pipe. The trap is provided with a float valve for automatically draining condensate and with a manual drain
valve.
On Full-Feature compressors a condensate trap is also installed downstream of the dryer. This trap is also
provided with a float valve for automatically draining condensate.
Cooling system
On air-cooled compressors, the air and oil coolers are cooled by fans.
Water-cooled compressors are provided with a cooling water system, including combined oil and air coolers.
2.4 Energy recovery system
General description
The maximum allowed pressure at the water side of the heat exchanger is 10 bar (145 psi).
The energy required in any compression process is mainly transformed into heat. The major part of the
compression heat is dissipated through the oil system. The Atlas Copco energy recovery systems are designed
to recover most of the above-mentioned heat as warm or hot water without any adverse influence on the
compressor performance.
After the compression stage, the oil is separated from the compressed air. The compressed air flows to the
aftercooler and the oil flows to the oil cooler. The energy in the oil can be recovered by installing a heat
exchanger in front of the oil cooler.
The energy recovery systems can be applied as low temperature rise / high water flow systems (e.g. central
heating in closed water circuits) or as high temperature rise / low water flow systems (e.g. pre-heating of
boiler feed water in open water circuits).
Main components
The system mainly comprises:
Oil/water heat exchanger (HE)
Energy recovery valve (Y152)
Oil by-pass valve (Y151)
Temperature sensors for water inlet and outlet
The necessary pipes, brackets, bolts, etc.
Installation
The package includes:
a general by-pass system, to shut down the energy recovery system
a by-pass system to prevent the oil outlet temperature from dropping below the minimum value.
When the Energy Recovery system is working, this by-pass system makes the oil flow through the Energy
Recovery heat exchanger instead of the normal oil cooler