“Setpoint 1” 7.0 bar
“Setpoint 2” 6.0 bar
“Indirect Stop Level” 0.3 bar
“Menu” “Modify”
F1 F2 F3
The regulator will not accept new values beyond the limitations.
It is possible to check the limitations which are valid for the parameter to be modified by
selecting “Limits”.
3.15 Fan motor settings
Control panel
Function
To modify the fan motor operation mode. Consult the menu flow in section Control programs.
Procedure
Starting from the Main screen (see section Main screen menu):
Press the key “Menu” (F1).
Press the arrow down key (1) until “Modify Parameters” is followed by a horizontal arrow.
Activate the menu by pressing the tabulator key (2).
The first item “Fan Motor” will be followed by a horizontal arrow.
Press the tabulator key (2) to activate the menu.
Press the arrow down key (1) until the option “Fan Operation Mode” is followed by the end marker; the
following screen appears:
Instruction book
2920 1728 05 57