11 Technical data
11.1 Readings on display
General
Control panel
Reference Units Reading
Outlet pressure bar(e) Depends on pressure set-point
Speed rpm Varies (controlled by regulator)
Maximum working pressure bar(e) See Compressor data.
At pressure set-point
Reference Units 4 bar(e)
60 psig
7 bar(e)
100 psig
9.5 bar(e)
140 psig
13.5 bar(e)
196 psig
Dp of air filter, approx. bar < 0.05 < 0.05 < 0.05 < 0.05
Dp of air filter, approx. psi < 0.73 < 0.73 < 0.73 < 0.73
Dp of oil separator bar < 0.8 < 0.8 < 0.8 < 0.8
Dp of oil separator psi <11.6 <11.6 <11.6 <11.6
Oil injection pressure,
approx.
bar 3.1 4.9 6.5 9.0
Oil injection pressure,
approx.
psi 45 70 95 130
Compressor outlet
temperature
˚C < 55 < 55 < 55 < 55
Compressor outlet
temperature
˚F <131 <131 <131 <131
Element out temperature ˚C < 100 < 100 < 100 < 100
Element out temperature ˚F <212 <212 <212 <212
Cooling medium
temperature
˚C < 46 < 46 < 46 < 46
Instruction book
2920 1728 05 147