Minimum air inletambient temperature ˚F 32
Maximum cooling air temperature, GA Pack, high ambient
temperature variant
˚C 55
Maximum cooling air temperature, GA Pack, high ambient
temperature variant
˚F 131
Maximum cooling air temperature, GA Full-Feature and Full-
Feature with DD filter, high ambient temperature variant
˚C 50
Maximum cooling air temperature, GA Full-Feature and Full-
Feature with DD filter, high ambient temperature variant
˚F 122
Maximum cooling air temperature, GA 110 VSD up to GA 160
VSD
˚C 46
Maximum cooling air temperature, GA 110 VSD up to GA 160
VSD
˚F 115
Minimum cooling air temperature ˚C 0
Minimum cooling air temperature ˚F 32
Maximum working pressure See section Compressor
data
Maximum cooling water inlet temperature ˚C 40
Maximum cooling water inlet temperature ˚F 104
Maximum cooling water outlet temperature (open systems) ˚C 50
Maximum cooling water outlet temperature (open systems) ˚F 122
Maximum cooling water outlet temperature (recirculating
systems)
˚C 60
Maximum cooling water outlet temperature (recirculating
systems)
˚F 140
Maximum cooling water inlet pressure bar(e) 10
Maximum cooling water inlet pressure psig 145
11.4 Settings of safety valve
Compressor type Setting
For GA compressors with a maximum working pressure of 8.5, 10 or 14 bar 15 bar (e)
For GA compressors with a maximum working pressure of 5.2, 6.9, 8.6, 10.4 or 13.8
bar
15 bar (e)
For GA compressors with a maximum working pressure of 75, 100, 125, 150 or 200
psi
218 psig