Units GA 110 VSD GA 132 VSD GA 160 VSD
Power input, air-cooled compressors
designed for high ambient
temperature
kW
--
159 194
Power input, air-cooled compressors
designed for high ambient
temperature
hp
--
213 260
Power input, GA W Pack kW 131 176 202
Power input, GA W Pack hp 176 236 271
Power input, GA W Full-Feature kW 135 166 205
Power input, GA W Full-Feature hp 181 223 275
Power input, GA W Full-Feature with
DD filter
kW
135
169 205
Power input, GA W Full-Feature with
DD filter
hp
181
227 275
Power input, water-cooled
compressors designed for high
ambient temperature
kW
--
157 191
Power input, water-cooled
compressors designed for high
ambient temperature
hp
--
211 256
Oil capacity, GA l 87 87 87
Oil capacity, GA US gal 23 23 23
Oil capacity, GA Imp gal 19.1 19.1 19.1
Oil capacity, GA cu.ft 3.07 3.07 3.07
Oil capacity, GA W l 74 74 74
Oil capacity, GA W US gal 19.6 19.6 19.6
Oil capacity, GA W Imp gal 16.3 16.3 16.3
Oil capacity, GA W cu.ft 2.61 2.61 2.61
Sound pressure level, GA dB(A) 68 68 69
Sound pressure level, GA W dB(A) 68 68 69
Maximum cooling water flow l/s 2.7 3.6 4.4
Maximum cooling water flow cfm 5.7 7.6 9.3
Minimum cooling water flow l/s 1.9 1.5 1.8
Minimum cooling water flow cfm 4.0 3.18 3.8
Data for GA 150 psi (10.4 bar) 60 Hz compressors
Units GA 110 VSD GA 132 VSD GA 160 VSD
Maximum working pressure, GA Pack bar(e) 10.9 10.9 10.9
Maximum working pressure, GA Pack psig 158.1 158.1 158.1
Maximum working pressure, GA Full-
Feature
bar(e)
10.7
10.7 10.7
Maximum working pressure, GA Full-
Feature
psig
155
155 155