Reference Description Reference Description
(1) Alarms (4) Warning
(2) OSCi Remaining (5) Low
(3) Level
Once the filter has reached a lifetime below 10%, this warning will remain active until new filters
are inserted correctly (sensor arm in tower 1 should rest on the filter edge!). When the new filters
are installed correctly and the percentage is above 10% (normally between 90% and 100%), the
warning will disappear automatically.
Overflow warning
This is a protection alarm, indicating that the water level in the OSCi is too high. The warning
LED will light up on the control panel of the Elektronikon™ Touch controller. In this case consult
section Problem solving. If the problem is not solved in time, water can escape from the OSCi
and leak onto the compressor frame and outside of the compressor. To consult the warning, tap
the alarm button:
Reference Description
(1) Compressor outlet
When tapped, the screen shows the OSCi overflow warning.
Instruction book