Loading...
That IP address will be excluded from the DNS server, so it will be reserved for the
controller.
Also get the correct Gateway and Subnet mask settings. For example:
IP = 10.25.43.200
Gateway = 10.25.42.250
Subnet mask = 255.255.254.0
Connect the controller to the company's network (LAN) by using a UTP cable (min. CAT 5e).
Adapt the network settings in the controller.
Put the controller in “advanced status”, scroll down to “Controller Settings” and swipe
left to “Ethernet settings”:
Switch off the ethernet communication to allow editing the settings:
Adapt IP Address
Adapt Gateway IP
Adapt Subnetmask
Switch on the Ethernet communication
Wait a few minutes so the controller can be connected to the LAN network
Configuration of the web server
The internal web server is designed and tested for Microsoft
®
Internet Explorer.
Also "Opera", "Mozilla Firefox", "Safari"and "Chrome" should work.
Viewing the controller data
All screen shots are indicative. The number of displayed fields depends on the selected
options.