Status screen with shutdown indication
Press on shutdown indication on the screen.
Shutdown screen, element outlet temperature
The above screen shows that the temperature at the outlet of the element is 116 ˚C. Actions:
Switch off the voltage and remedy the problem cause.
After remedying and when the shutdown condition has disappeared, switch on the voltage
and restart the unit.
Other shutdown causes
In case the unit is shut down (or cannot start) by one of following causes: