EasyManuals Logo

Atlas Copco PNS 1250 Cud S3A/T3 APP User Manual

Atlas Copco PNS 1250 Cud S3A/T3 APP
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #40 background imageLoading...
Page #40 background image
- 41 -
The engine starts cranking.
The engine cranks until 800 RPM is reached.
If 800 RPM is not reached within 30 seconds, the
starting procedure is cancelled and the engine will
rest for some time. (Resting time depends on
cranking time.)
The engine starts running at idle speed.
The engine runs at minimum RPM until the
engine's coolant temperature reaches 40°C, with a
minimum time of 30 seconds and a maximum
time of 300 seconds.
800RPM
324RPM
0RPM
MAIN VIEW
ENGINE CRANKING
0.0 bar324RPM1286h
40%
Active Buttons:
Stop Button
(to initiate Stop command)
Load Button
(to activate Automatic Load)
Measurement View Button
Settings View Button
Alarms View Button
54s
0s
MAIN VIEW
ENGINE RESTING
0.0 bar324RPM1286h
120s
40%
MAIN VIEW
ENGINE WARMING UP
3.3 bar1200RPM1286h
40°C
25°C
13°C
300s
76s
0s
40%

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco PNS 1250 Cud S3A/T3 APP and is the answer not in the manual?

Atlas Copco PNS 1250 Cud S3A/T3 APP Specifications

General IconGeneral
BrandAtlas Copco
ModelPNS 1250 Cud S3A/T3 APP
CategoryAir Compressor
LanguageEnglish

Related product manuals