3-8
ELECTRICAL PROTECTION: SYSTEM 85 AND DEFINITY GENERIC 2 WITH TRADITIONAL MODULES
TABLE 3-1. Loop Ranges for Protected Hybrid Terminals
Terminal
7203
7205
MET
Protector
Adjuncts
4C3S-75*
ITW
PDP
4C3S-75*
ITW
PDP
4C3S-75*
ITW
PDP
4C3S-75*
ITW
PDP
4C3S-75*
ITW
PDP
0
0
0
0
0
0
1
1
1
2
2
2
0
0
0
Range Ft (M)
24AWG
3000 (914)
3000 (914)
3000 (914)
3000 (914)
3000 (914)
3000 (914)
1750 (533)
1750 (533)
1750 (533)
1000 (305)
1000 (305)
1000 (305)
1000 (305)
1000 (305)
1000 (305)
26AWG
2300 (701 )
2300 (701)
2300 (701)
2000 (610)
2000 (610)
2000 (610)
1100 (335)
1100 (335)
1100 (335)
750 (229)
750 (229)
750 (229)
1000 (305)
1000 (305)
1000 (305)
*This is the recommended module protector.
TABLE 3-2. Loop Ranges for Protected Digital Terminals
Range Ft (M)
Terminal
Protector
24AWG
26AWG
Digital Set
4C3S-75*
3400 (1036)
2200 (671)
ITW
3400 (1036)
2200 (671)
PDP 3400 (1036) 2200 (671)
DLP
5000 (1524)
4000 (1219)
*This is the recommended module protector.