60
4OPERATION
4.2 SETTING AND MONITORING
ALS
350
450
4.2.6 If errors occur
Warning messages
If the machine control system detects a malfunction,
but the labelling operation does not have to be inter-
rupted:
A warning message appears on the LED-indicator
of the operator panel.
A warning message is displayed in the format
W_nn:
W stands for warning,
nn is a two-digit numerical code.
An electronic signal is issued at the same time. The
signal can be further processed by an external con-
trol system.
For an explanation of the warning messages and
notes on fault elimination, see chapter Operational
malfunctions.
Example [64]:
The current labelling speed is too high.
The warning message W__4 appears on the opera-
tor panel.
An electronic signal is sent to the system control.
The system control issues an additional warning
tone.
Error messages
If the machine control system detects a serious mal-
function:
The labelling operation is automatically halted.
An error message appears on the LED-indicator of
the operator panel.
A warning message is displayed in the format E_nn:
E stands for error,
nn is a two-digit numerical code.
An electronic signal is issued at the same time. The
signal can be further processed by an external con-
trol system.
For an explanation of the error messages and notes
on fault elimination, see chapter Operational mal-
functions.
Example [65]:
The label ribbon is torn.
The error message E__6 appears on the operator
panel.
An electronic signal is sent to the system control.
The system control issues an additonal warning
tone and stops the conveyor belt.
[64] Example: The warning message W__4 is displayed on the op-
erator panel
[65] Example: The error message E__6 is displayed on the operator
panel