77
4OPERATION
4.4 SETTINGS IN THE EXTENDED MENU
ALS
350
450
4.4.12 Number of unlabelled products
(MLAB)
If products do not get labelled, the operator receives
the warning message W_0 at the operator panel. If too
many products in a row do not get labelled, the machine
stops. The error message E_11 appears at the opera-
tor panel. Using the MLAB function, you can determine
how many products in a row are allowed to be unla-
belled before the machine stops.
Example [84]:
MLAB is set to value 2. The machine stops after three
products in a row are not labelled. The error message
E__11 appears on the operator panel.
In the extended menu:
£ Call up the MLAB function.
£ Set the desired value.
– Possible settings: 0 ... 10 products
£ Confirm the setting using the ENTER key and exit
the MLAB function.
4.4.13 Electronic transmission ratio
of the RPM transmitter (EGRA)
– Compensation factor for RPM transmitter when op-
erating with automatic dispensing speed adjustment
– Refer to Chapter Automatic dispensing speed
(APSF), Page 80.
[84] Three products in a row were not labelled.