EasyManua.ls Logo

Avery Dennison ALS 350 - Critical Error Messages and Codes

Avery Dennison ALS 350
101 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
91
6OPERATIONAL MALFUNCTIONS
6.2 ERROR MESSAGES
ALS
350
450
6.2.1 If a malfunction occurs
If the control system detects a serious error:
The labelling operation is stopped.
An error code is displayed on the operator panel.
If the cause of the error has been eliminated:
£ Acknowledge the error message by pressing the
ENTER key.
6.2.2 Error codes
Message Description Possible causes and remedies
E__1 The loop space is not filled. Label roll empty:
£ Replace label roll.
Pressure roller not closed:
£ Swing up the pressure roller on the drive roller unit’s un-
wind unit and return it to its position pressing against the
roller. The pressure roller clicks neatly into its operating
position.
Unwind unit drive defective:
Repair by servicing technician is required; refer to
service guide
The photoelectric sensor in the loop
space does not actuate.
Reflective surface is dirty:
£ Clean the reflective surface.
Use of very bright labels or
Sensor potentiometer out of adjustment or
Sensor defective:
Adjustment/replacement by servicing technician is
required; refer to service guide
6.2 ERROR MESSAGES

Table of Contents

Related product manuals