EasyManua.ls Logo

Avery Dennison ALS 350 - Page 90

Avery Dennison ALS 350
101 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
90
6OPERATIONAL MALFUNCTIONS
6.1 WARNING MESSAGES
ALS
350
450
W__2 Memory errors
Factory settings are activated, see
Appendix.
CPU battery is discharged after a long shut-down period of
the machine:
£ Leave the machine switched on for some time to re-
charge the battery
If the accumulatorerror occurs frequently:
£Have the CPU battery replaced by the customer
service.
Settings no longer available after software update.
Settings must be input again by a servicing techni-
cian; refer to service guide.
W__3 Too many labels between label stop
sensor and dispensing edge.
Label stop sensor must be adjusted by servicing
technician; refer to service guide.
W__4 Dispensing speed is too high.
This negatively affects position
accuracy.
£ Reduce dispensing speed (VELO), if the warning-
message is frequently displayed for long periods.
For automatic dispensing speed (APSF):
A check of the EGRA function is required
W__5 The roll diameter control (optional)
reports the end of the label roll.
£ Insert new labelling material.
W__6 Data transmission error at the V24
interface
The cables, plug connections, and interface param-
eters must be checked by servicing technicians; re-
fer to service guide
W__7 Label position on the product too
close to the product’s leading edge
and high dispensing speed
£ Increase the setting value for POS, decrease dispensing
speed (VELO).
If this is not possible or the warning message
reappears:
The settings in the configuration menu must be
checked by servicing technicians; refer to service
guide.
Message Description Possible causes and remedies