4OPERATION
4.6 APPLICATOR (OPTIONAL)
ALS
350
450
4.6.2 Functions in the extended
menu
Please observe the following:
CAUTION!
Erroneous settings can lead to production
setbacks, damage to the machine and sys-
tem, and can even cause work-related acci-
dents!
Only specially trained and instructed per-
sonnel may alter the settings in the ex-
tended menu.
Calling up the extended menu.
£ Simultaneously press the NEXT and PRIOR keys.
CODE appears on the LED display.
£ Enter the password [87].
The following appears on the LED display for ap-
prox. 1 second:
****
The extended menu is active.
Applicator type (APPL)
Set the applicator type used or switch off the appli-
cator.
In the extended menu:
£ Call up the APPL function.
£ Set the desired type.
Possible settings:
ASA Air Stream Applicator
EP: Electro-pneumatic applicator
REVP: Reverse electro-pneumatic applicator
DIR: Dispense directly from the dispenser head
without using the applicator
£ Confirm the setting using the ENTER key and exit
the function.
[87] Key sequence (password) for the extended menu